The polarimeter P3000 is the economical solution for standard applications for which a measurement accuracy of ±0.01° is sufficient. It performs its tasks in the record measurement time of approx. 1 s that you are familiar with from our digital polarimeters. The measured values are optionally displayed as an optical angle of rotation or on the international sugar scale of the ICUMSA. If desired, they can be printed on a serial ASCII printer. Thanks to the reliable temperature compensation, it is possible to measure at any temperature specified in the ICUMSA; the results will then be converted to the value for 20 °C.
The P3000 Economy polarimeters can be used for a variety of applications in the pharmaceutical, chemical and sugar industries as well as in hospitals and pharmacies.
A comprehensive overview of typical applications with the polarimeters of the P8000 series can be found in our campus article on polarimeter applications.
Working in accordance with standards and guidelines facilitates the comparison of the measured values and ensures their quality. The polarimeters P3000 meet the requirements of the following standards:
Polarimeter Standards (PDF, 83 KB)
Any questions?
Feel free to contact us, we will assist you in choosing the right polarimeter for you.
The polarimeter model P3000 Economy is used in the laboratory and research for the measurement of a wide variety of samples, eg. drugs, raw and auxiliary materials. We have bundled our expertise in an overview of the samples that can be measured with our instruments.
For your free download:
(All values have been compiled with best accuracy, but this information is supplied without liability.)
Polarimeter samples and their optical rotation (PDF, 122 KB)
Any questions?
Get in contact with us, we will assist you in choosing a suitable polarimeter.
P3000 | |
---|---|
SCALES | Optical rotation [°] Int. sugar scale [°Z] |
MEASUREMENT RANGES | ±90° ±259 °Z |
MEASUREMENT ACCURACY | ±0.01° ±0.01 °Z |
RESOLUTION | 0.01° 0.01 °Z |
TEMPERATURE | |
TEMPERATURE MEASUREMENT | With temperature probe PRT-E or PRT-T |
TEMPERATURE MEASUREMENT RANGE | 0–99.9 °C |
TEMPERATURE MEASUREMENT RESOLUTION | 0.1 °C |
TEMPERATURE MEASUREMENT ACCURACY | ±0.1 °C |
TEMPERATURE CONTROL | Can be retrofitted (requires Circulation Thermostat PT31 or PT80, sample chamber bushing P8020 and temperature-controlled measurement tube PRG-100-ET) |
OTHER SPECIFICATIONS | |
MEASUREMENT PERIOD ±90° | Approx. 1 s |
LIGHT SOURCE | 1 LED with filter |
WAVELENGTH | 589 nm |