As a standard, the refractometer models DR6000-T and DR6000-TF are equipped with a Peltier element that controls the temperature of the sample up to 80 °C. There are four different models available for different requirements on accuracy, resolution and measurement range whereby you can access the same operation and functionality.
pibus leo.
Refractometers are also designed and used in accordance with standards. Standards in refractometry regulate, under the aspect of “best practice”, the environmental conditions and sample preparation as well as measurement tolerances, properties and equipment features of a device or certificates of calibration equipment and testing instruments. Whoever uses refractometers according to normative specifications can guarantee that measurements are correct and work according to reproducible procedures.
In order to make it easier for you to choose the right refractometer for your application, you will find for free download an overview of all standards and guidelines known to us in which refractometry is referred to.
Refractometer standards (PDF, 79 KB)Any questions? Get in contact with us, we will assist you in choosing the right refractometer for you.
For your free download: (All values have been compiled with best accuracy, but this information is supplied without liability.) Refractometer samples (PDF, 189 KB)
Any questions? Get in contact with us, we will assist you in choosing a suitable refractometer.DR6000-T | DR6100-T | DR6200-T | DR6300-T | |
---|---|---|---|---|
MEASUREMENT DATA | ||||
SCALES | Refractive index (nD) Concentration of sucrose, glucose, fructose and invert sugar [%Brix], User-defined | |||
MEASUREMENT RANGE | nD 1.3200–1.5800 0–95 %Brix | nD 1.3200–1.7000 0–95 %Brix | nD 1.32000–1.58000 0–95 %Brix | nD 1.32000–1.70000 0–95 %Brix |
MEASUREMENT ACCURACY | nD ±0.0001 ±0.1 %Brix | nD ±0.00002 ±0.02 %Brix | ||
RESOLUTION | nD 0.0001 0.1 %Brix | nD 0.00001 0.01 %Brix | ||
MEASUREMENT PERIOD | approx. 4 s | |||
MEASUREMENT PRISM | Sapphire | |||
LIGHT SOURCE | LED | |||
WAVELENGTH | 589 nm | |||
TEMPERATURE DATA | ||||
TEMPERATURE CONTROL | With integrated Peltier temperature control | |||
TEMP. CONTROL RANGE | 10–80 °C | |||
ACCURACY OF TEMP. CONTROL | ±0.1 °C | |||
TEMPERATURE COMPENSATION | Can be activated (ICUMSA or freely definable) | |||
TEMPERATURE MEASUREMENT | With integrated temperature sensor Pt100 | |||
TEMPERATURE MEASUREMENT RANGE | 10–80 °C | |||
TEMP. MEASUREMENT ACCURACY | ±0.1 °C | |||
TEMP. MEASUREMENT RESOLUTION | 0.1 °C |